Where solar economics meet market opportunity.
An auditable, county-level decision platform for energy value, solar productivity, multifamily concentration, and affordable-housing opportunity.
Return on Cost by county:
County solar economics with one California export scenario. Select or hover over a county to inspect annual modeled value and return on cost.
Return on Cost (%)
Annual modeled electricity value ÷ $2,760/kW DC; CA: 50% at retail + 50% at 6¢ export; other states: gross retail-equivalent. Not actual savings.
Top U.S. markets by annual retail value
| RANK | COUNTY | RATE CLASS BENCHMARK | PV YIELD | VALUE / kWdc / YR | RATE SOURCE | ACTION |
|---|
The upper-right corner is the opportunity
Every dot is one county. Upper-right: top third on both electricity price and annual solar yield.
Not just the sunniest.
The best screened markets combine high-priced electricity with high PV output. A high combined dollar value can still come from one exceptionally strong input; the quadrant requires both to be strong.
Put up to five counties side by side
Use map selections or search below. Prices, specific yields, and confidence remain visible together.
Solar value is only half the market.
Overlay actual rental multifamily concentration and affordable-housing opportunities. These are separate from the county solar/electricity calculations.
County-level renter-occupied units in structures with five or more apartments (B25032). This is unit stock, not building counts.
County project and unit counts from HUD-reported LIHTC records. This is housing stock, not a list of current solar leads.
Which counties contain the opportunity?
No verified county inventory has been loaded. Import ACS/HUD counts to activate the density ranking. The existing solar/rate data is still complete.
What could solar be worth at a multifamily property?
An indicative calculation using the selected county yield and adjustable utility/ownership assumptions. Not a proposal, NEM forecast, or actual bill-savings estimate.
Annual energy & potential value
Monthly production for this system
PVGIS modeled shape · kWh ACCreate a transparent market-priority ranking
Weights operate on percentile-normalized county measures. Missing inventory inputs are never invented; unavailable factors are excluded and all active weights are renormalized.
| RANK | COUNTY | MARKET SCORE | RETAIL VALUE | PV YIELD | RATE QUALITY |
|---|
Auditable by design.
County price × standardized annual PV output. Existing v1 method preserved.
Standardized PVGIS 20° south-facing 1 kWdc system output.
Renter-occupied units in 5+ unit structures, when verified ACS data is loaded.
County LIHTC property count, when verified HUD data is loaded.
Utility-specific benchmark ranked above fallback state average.
What the numbers mean—and what they don't.
Solar productivity
kWh AC per kW DC annually. PVGIS 5.3 with ERA5 historical weather (2005–2023), crystalline silicon, 20° fixed tilt, south-facing, ventilated mounting, 14% system-loss input. One Census county internal reference point per county. Same setup everywhere. The 595 W estimate is yield multiplied by 0.595.
PVGIS official documentation ↗Electricity price
2025 EIA annual realized average $/kWh. Utility-specific benchmark where a defensible territory assignment is available, or an explicitly labeled state average. Includes fixed-charge revenue. Not a marginal avoided-cost tariff or solar net-metering rate. Residential and commercial sectors stay separate.
EIA-861 electricity data ↗Combined value
Modeled annual kWh/kWdc × EIA average retail $/kWh = annual dollars/kWdc. A gross retail-value screening index, not a building's actual achievable savings or a return-on-investment calculation.
Download original county study ↗High on both
Both rate and solar yield at or above the national two-thirds quantile (equal weight per county). Thresholds remain fixed under geographic filtering. A high combined value does not guarantee passing this two-factor test.
Multifamily inventory
2024 ACS five-year B25032 counts renter-occupied homes in 5+ unit structures, not the number of apartment buildings. HUD LIHTC records are historical properties placed in service, not current sales prospects. These layers are populated only when the official inventory source files are bundled by the build or explicitly imported. A missing dataset remains unknown, never zero. Distinct HUD IDs may represent separate phases or repeat awards at the same site.
ACS B25032 ↗HUD LIHTC database ↗Multifamily tariffs / ETB
Tenant meters may take residential rates; common/master meters can use either sector. Real bill savings requires actual schedules, self-consumption, export tariffs, eligibility, and ownership allocation. No ETB tariff rates are claimed to be imported until the harvest ZIP is supplied.
Solar geographic refinement
V2 includes an executable multi-point PVGIS validation script and importer. Until that rerun is performed, the base map still uses the original single county reference point; a neighboring-county difference is not a substitute for within-county simulation.
2026 price comparison
The rate-shift layer compares EIA state residential or commercial averages for January-August 2026 versus January-August 2025 (Electric Power Monthly Table 5.6.B; released October 23, 2026). 2026 is preliminary. Each county inherits its state result; this is not a utility-specific tariff change and it does not replace the original 2025 annual benchmark. Optional ETB tariff snapshots remain separate.