ShineSHINEIQMARKET ATLASMULTIFAMILY SOLAR INTELLIGENCE
3,144 counties modeled V3 · Return on cost
NATIONAL MULTIFAMILY OPPORTUNITY INTELLIGENCE

Where solar economics meet market opportunity.

An auditable, county-level decision platform for energy value, solar productivity, multifamily concentration, and affordable-housing opportunity.

Preparing market metrics…
SHINEIQ · MARKET ATLAS V3

Return on Cost by county:

County solar economics with one California export scenario. Select or hover over a county to inspect annual modeled value and return on cost.

INSTALLED COST ASSUMPTION$2.76 / Wdc$2,760 per installed kW DC
CONTIGUOUS U.S. · AK + HI INSETS

Return on Cost (%)

Annual modeled electricity value ÷ $2,760/kW DC; CA: 50% at retail + 50% at 6¢ export; other states: gross retail-equivalent. Not actual savings.

ALASKAHAWAII
How the percentage works: Annual return on cost = modeled annual electricity value ($/kW DC/year) ÷ $2,760 installed cost per kW DC × 100. California: 50% of generation valued at the selected retail benchmark, 50% exported at 6¢/kWh. Other states: 100% gross retail-equivalent screening. These are screening assumptions—not verified bill savings, net financial return, IRR, or a universal California export tariff.
ⓘ County solar modeled at a Census reference location. State-price estimates are visibly distinguished.
COUNTY LEADERBOARD

Top U.S. markets by annual retail value

RANKCOUNTYRATE CLASS BENCHMARKPV YIELDVALUE / kWdc / YRRATE SOURCEACTION
THE CEO VIEW

The upper-right corner is the opportunity

Every dot is one county. Upper-right: top third on both electricity price and annual solar yield.

Dynamic filters
QUADRANT EXPLAINED

Not just the sunniest.

The best screened markets combine high-priced electricity with high PV output. A high combined dollar value can still come from one exceptionally strong input; the quadrant requires both to be strong.

PRICE THRESHOLD–Two-thirds national quantile
SOLAR THRESHOLD1,449 kWh/kWdcTwo-thirds national quantile
QUALIFYING COUNTIES IN VIEW–Fixed nationwide cutoffs
INTERACTIVE MARKET COMPARISON

Put up to five counties side by side

Use map selections or search below. Prices, specific yields, and confidence remain visible together.

HOUSING CONCENTRATION

Solar value is only half the market.

Overlay actual rental multifamily concentration and affordable-housing opportunities. These are separate from the county solar/electricity calculations.

▥
U.S. Census ACS — 5+ unit renter-occupied homes

County-level renter-occupied units in structures with five or more apartments (B25032). This is unit stock, not building counts.

NOT LOADED
⌂
HUD LIHTC — property-level inventory

County project and unit counts from HUD-reported LIHTC records. This is housing stock, not a list of current solar leads.

NOT LOADED
HUD source ↗
COVERAGE-FIRST RANKING

Which counties contain the opportunity?

No verified county inventory has been loaded. Import ACS/HUD counts to activate the density ranking. The existing solar/rate data is still complete.

ShineScout / HubSpot lead overlays should be added later as access-controlled company data, never silently mixed into public national inventory.
PROJECT-SCALE SENSITIVITY

What could solar be worth at a multifamily property?

An indicative calculation using the selected county yield and adjustable utility/ownership assumptions. Not a proposal, NEM forecast, or actual bill-savings estimate.

ILLUSTRATIVE OUTPUT

Annual energy & potential value

Monthly production for this system

PVGIS modeled shape · kWh AC
Does not include storage, demand charges, time-of-use matching, system shading, tax benefits, inflation, degradation, financing, interconnection cost, or individual tariff validation. Positive modeled value is not necessarily realizable by the asset owner.
CUSTOM STRATEGY MODEL

Create a transparent market-priority ranking

Weights operate on percentile-normalized county measures. Missing inventory inputs are never invented; unavailable factors are excluded and all active weights are renormalized.

RANKCOUNTYMARKET SCORERETAIL VALUEPV YIELDRATE QUALITY
MODEL GOVERNANCE

Auditable by design.

01
Value

County price × standardized annual PV output. Existing v1 method preserved.

02
Solar potential

Standardized PVGIS 20° south-facing 1 kWdc system output.

03
Multifamily depth

Renter-occupied units in 5+ unit structures, when verified ACS data is loaded.

04
LIHTC presence

County LIHTC property count, when verified HUD data is loaded.

05
Data confidence

Utility-specific benchmark ranked above fallback state average.

A market score is a screening aid, not a financial underwriting prediction. Housing inventory must be loaded to fully activate housing factors.
AUDIT TRAIL

What the numbers mean—and what they don't.

01

Solar productivity

kWh AC per kW DC annually. PVGIS 5.3 with ERA5 historical weather (2005–2023), crystalline silicon, 20° fixed tilt, south-facing, ventilated mounting, 14% system-loss input. One Census county internal reference point per county. Same setup everywhere. The 595 W estimate is yield multiplied by 0.595.

PVGIS official documentation ↗
02

Electricity price

2025 EIA annual realized average $/kWh. Utility-specific benchmark where a defensible territory assignment is available, or an explicitly labeled state average. Includes fixed-charge revenue. Not a marginal avoided-cost tariff or solar net-metering rate. Residential and commercial sectors stay separate.

EIA-861 electricity data ↗
03

Combined value

Modeled annual kWh/kWdc × EIA average retail $/kWh = annual dollars/kWdc. A gross retail-value screening index, not a building's actual achievable savings or a return-on-investment calculation.

Download original county study ↗
04

High on both

Both rate and solar yield at or above the national two-thirds quantile (equal weight per county). Thresholds remain fixed under geographic filtering. A high combined value does not guarantee passing this two-factor test.

05

Multifamily inventory

2024 ACS five-year B25032 counts renter-occupied homes in 5+ unit structures, not the number of apartment buildings. HUD LIHTC records are historical properties placed in service, not current sales prospects. These layers are populated only when the official inventory source files are bundled by the build or explicitly imported. A missing dataset remains unknown, never zero. Distinct HUD IDs may represent separate phases or repeat awards at the same site.

ACS B25032 ↗HUD LIHTC database ↗
06

Multifamily tariffs / ETB

Tenant meters may take residential rates; common/master meters can use either sector. Real bill savings requires actual schedules, self-consumption, export tariffs, eligibility, and ownership allocation. No ETB tariff rates are claimed to be imported until the harvest ZIP is supplied.

07

Solar geographic refinement

V2 includes an executable multi-point PVGIS validation script and importer. Until that rerun is performed, the base map still uses the original single county reference point; a neighboring-county difference is not a substitute for within-county simulation.

08

2026 price comparison

The rate-shift layer compares EIA state residential or commercial averages for January-August 2026 versus January-August 2025 (Electric Power Monthly Table 5.6.B; released October 23, 2026). 2026 is preliminary. Each county inherits its state result; this is not a utility-specific tariff change and it does not replace the original 2025 annual benchmark. Optional ETB tariff snapshots remain separate.